Scilab Website | Contribute with GitLab | Mailing list archives | ATOMS toolboxes
Scilab Online Help
5.5.0 - Русский

Change language to:
English - Français - 日本語 - Português -

Please note that the recommended version of Scilab is 2025.0.0. This page might be outdated.
See the recommended documentation of this function

Справка Scilab >> CACSD > kpure

kpure

continuous SISO system limit feedback gain

Calling Sequence

K=kpure(sys [,tol])
[K,R]=kpure(sys [,tol])

Arguments

sys

SISO linear system (syslin)

tol

a positive scalar. tolerance used to determine if a root is imaginary or not. The default value is 1e-6

K

Real vector, the vector of gains for which at least one closed loop pole is imaginary.

R

Complex vector, the imaginary closed loop poles associated with the values of K.

Description

K=kpure(sys) computes the gains K such that the system sys feedback by K(i) (sys/.K(i)) has poles on imaginary axis.

Examples

num=real(poly([-1+%i, -1-%i, -1+8*%i  -1-8*%i],'s'));
den=real(poly([0.5 0.5  -6+7*%i  -6-7*%i  -3 -7 -11],'s'));
h=num/den;

[K,Y]=kpure(h)
clf();evans(h)
plot(real(Y),imag(Y),'+r')
num=real(poly([-1+%i*1, -1-%i*1, 2+%i*8  2-%i*8 -2.5+%i*13 -2.5-%i*13],'s'));
den=real(poly([1 1 3+%i*3 3-%i*3 -15+%i*7  -15-%i*7  -3 -7 -11],'s'));
h=num/den;

[K,Y]=kpure(h)
clf();evans(h,100000)
plot(real(Y),imag(Y),'+r')

See Also

  • evans — Evans root locus
  • krac2 — continuous SISO system limit feedback gain
Report an issue
<< invsyslin CACSD krac2 >>

Copyright (c) 2022-2024 (Dassault Systèmes)
Copyright (c) 2017-2022 (ESI Group)
Copyright (c) 2011-2017 (Scilab Enterprises)
Copyright (c) 1989-2012 (INRIA)
Copyright (c) 1989-2007 (ENPC)
with contributors
Last updated:
Fri Apr 11 14:19:38 CEST 2014