wfir
linear-phase FIR filters
Syntax
[wft,wfm,fr]=wfir(ftype,forder,cfreq,wtype,fpar)
Arguments
- ftype
- string : - 'lp','hp','bp','sb'(filter type)
- forder
- Filter order (pos integer)(odd for - ftype='hp'or- 'sb')
- cfreq
- 2-vector of cutoff frequencies ( - 0<cfreq(1),cfreq(2)<.5) only- cfreq(1)is used when- ftype='lp'or- 'hp'
- wtype
- Window type ( - 're','tr','hm','hn','kr','ch')
- fpar
- 2-vector of window parameters. Kaiser window - fpar(1)>0 fpar(2)=0. Chebyshev window- fpar(1)>0, fpar(2)<0or- fpar(1)<0, 0<fpar(2)<.5
- wft
- time domain filter coefficients 
- wfm
- frequency domain filter response on the grid fr 
- fr
- Frequency grid 
Description
Function which makes linear-phase, FIR low-pass, band-pass, high-pass, and stop-band filters using the windowing technique. Works interactively if called with no arguments.
Examples
[h,hm,fr]=wfir("lp",33,[.2 0],"hm",[0 0])
| Report an issue | ||
| << trans | Filters | wfir_gui >> |