Scilab Website | Contribute with GitLab | Mailing list archives | ATOMS toolboxes
Scilab Online Help
6.1.0 - Português

Change language to:
English - Français - 日本語 - Русский

Please note that the recommended version of Scilab is 2025.0.0. This page might be outdated.
See the recommended documentation of this function

Ajuda do Scilab >> Xcos > palettes > Discontinuities_pal > RATELIMITER

RATELIMITER

Rate limiter

Block Screenshot

Description

The Rate Limiter block limits the first derivative of the signal passing through it. The output changes no faster than the specified limit.

Parameters

  • Max slope

    The limit of the derivative of an increasing input signal.

    Properties : Type 'vec' of size 1

  • Min slope

    The limit of the derivative of a decreasing input signal.

    Properties : Type 'vec' of size 1

Default properties

  • always active: no

  • direct-feedthrough: yes

  • zero-crossing: no

  • mode: no

  • regular inputs:

    - port 1 : size [1,1] / type 1

  • regular outputs:

    - port 1 : size [1,1] / type 1

  • number/sizes of activation inputs: 0

  • number/sizes of activation outputs: 0

  • continuous-time state: no

  • discrete-time state: no

  • object discrete-time state: no

  • name of computational function: ratelimiter

Interfacing function

  • SCI/modules/scicos_blocks/macros/Misc/RATELIMITER.sci

Computational function

  • SCI/modules/scicos_blocks/src/c/ratelimiter.c (Type 4)

Example

Let's limit the output slope to 1/3:

Report an issue
<< HYSTHERESIS Discontinuities_pal SATURATION >>

Copyright (c) 2022-2024 (Dassault Systèmes)
Copyright (c) 2017-2022 (ESI Group)
Copyright (c) 2011-2017 (Scilab Enterprises)
Copyright (c) 1989-2012 (INRIA)
Copyright (c) 1989-2007 (ENPC)
with contributors
Last updated:
Tue Feb 25 08:52:34 CET 2020