Please note that the recommended version of Scilab is 2026.0.0. This page might be outdated.
See the recommended documentation of this function
VanneReglante
Thermal-hydraulic control valve
Block Screenshot

Contents
Palette
Description
The VanneReglante block represents a variable orifice control valve. The flow rate through the valve is proportional to the valve opening, ,

where is the valve opening, is the pressure difference, and is the flow rate. This model is only used for the laminar flow regimes. is a constant depending on the valve geometry and mass density of fluid.
Dialog box

- Cvmax - Cvmax (maximum opening of the valve) - Properties : Type 'vec' of size -1. 
- p_rho - Fluid density - Properties : Type 'vec' of size -1. 
Default properties
- Inputs : - Modelica variable name : 'C1' - Implicit variable. 
- Modelica variable name : 'Ouv' - Explicit variable. 
 
- Outputs : - Modelica variable name : 'C2' - Implicit variable. 
 
- Parameters : - Modelica parameter name : 'Cvmax' - Default value : 8005.42 - Is a state variable : no. 
- Modelica parameter name : 'p_rho' - Default value : 0 - Is a state variable : no. 
 
- File name of the model : VanneReglante 
Interfacing function
- SCI/modules/scicos_blocks/macros/Hydraulics/VanneReglante.sci 
Modelica model
- SCI/modules/scicos_blocks/macros/Hydraulics/VanneReglante.mo 
| Report an issue | ||
| << SourceP | Thermohydraulics palette | User defined functions palette >> |