Scilab Website | Contribute with GitLab | Mailing list archives | ATOMS toolboxes
Scilab Online Help
5.4.0 - Français

Change language to:
English - 日本語 - Português - Русский

Please note that the recommended version of Scilab is 2025.0.0. This page might be outdated.
See the recommended documentation of this function

Aide Scilab >> CACSD (Computer Aided Control Systems Design) > lqg_ltr

lqg_ltr

LQG with loop transform recovery

Calling Sequence

[kf,kc]=lqg_ltr(sl,mu,ro)

Arguments

sl

linear system in state-space form (syslin list)

mu,ro

real positive numbers chosen ``small enough''

kf,kc

controller and observer Kalman gains.

Description

returns the Kalman gains for:

x = a*x + b*u + l*w1   
(sl)
y = c*x + mu*I*w2

z = h*x

Cost function:

/+oo
|
J    = E(| [z(t)'*z(t) + ro^2*u(t)'*u(t)]dt)
lqg     |
/ 0

The lqg/ltr approach looks for L,mu,H,ro such that: J(lqg) = J(freq) where

/+oo        *  *           *
J    =  | tr[S  W  W  S ] + tr[T  T]dw
freq   |
/0

and

S = (I + G*K)^(-1)  
T = G*K*(I+G*K)^(-1)

See Also

  • syslin — définition d'un système dynamique linéaire
Report an issue
<< lqg2stan CACSD (Computer Aided Control Systems Design) lqr >>

Copyright (c) 2022-2024 (Dassault Systèmes)
Copyright (c) 2017-2022 (ESI Group)
Copyright (c) 2011-2017 (Scilab Enterprises)
Copyright (c) 1989-2012 (INRIA)
Copyright (c) 1989-2007 (ENPC)
with contributors
Last updated:
Mon Oct 01 17:37:17 CEST 2012