PerteDP
Thermal-hydraulic pipe
Block Screenshot
Description
A PertDP block represents a hydraulic pipe with linear resistance losses. This component represents a hydraulic resistance and pressure loss is directly proportional to the flow rate. Conventionally, the flow direction is the positive when fluid flows from the black port to the white port. The pressure loss is obtained with :
Ploss = Pblack - PwhiteThe key parameters of this block are the pipes' length, the pipe's diameter, inlet and outlet altitudes, and some other thermal-hydraulic coefficients.
Parameters
Longueur du tube : L (m)
Length of pipe
Properties : Type 'vec' of size -1.
Diamètre interne du tube : D (m)
Pipe diameter
Properties : Type 'vec' of size -1.
Coefficient de perte de charge-frottement(S.U) : lambda
Coefficient of thermohydraluc resistance
Properties : Type 'vec' of size -1.
Altitude entrée tuyauterie : z1 (m)
Altitude of the first port (z1)
Properties : Type 'vec' of size -1.
Altitude sortie tuyauterie : z2 (m)
Altitude of the second port (z2)
Properties : Type 'vec' of size -1.
Si 0, masse volumique imposée fu fluide : p_rho (kg/m3)
Fluid density
Properties : Type 'vec' of size -1.
Default properties
Inputs :
Modelica variable name : 'C1'
Implicit variable.
Outputs :
Modelica variable name : 'C2'
Implicit variable.
Parameters :
Modelica parameter name : 'L'
Default value : 10
Is a state variable : no.
Modelica parameter name : 'D'
Default value : 0.2
Is a state variable : no.
Modelica parameter name : 'lambda'
Default value : 0.03
Is a state variable : no.
Modelica parameter name : 'z1'
Default value : 0
Is a state variable : no.
Modelica parameter name : 'z2'
Default value : 0
Is a state variable : no.
Modelica parameter name : 'p_rho'
Default value : 0
Is a state variable : no.
File name of the model : PerteDP
Interfacing function
SCI/modules/scicos_blocks/macros/Hydraulics/PerteDP.sci
Modelica model
SCI/modules/scicos_blocks/macros/Hydraulics/PerteDP.mo
Report an issue | ||
<< Flowmeter | Thermohydraulics palette | PuitsP >> |