Bache
Thermal-hydraulic tank (reservoir)
Block Screenshot
Description
The Bache block represents a thermal-hydraulic tank or reservoir. This block has two inlets and two outlets whose altitudes can be changed by the user. Conventionally, for input ports (black ports) flow direction is positive when fluid flows into the tank. On the other hand, for output ports (white ports) flow direction is positive when fluid flows out of the tank. The user can set the surface area of the tank, the initial temperature and initial level of the fluid in the tank. If an input or output port is left unused, it should be blocked by a stopper block.
Parameters
Pression dans le ciel de la bache : Patm (Pa)
Atmospheric pressure inside the tank.
Properties : Type 'vec' of size -1.
Section de la bache : A (m2)
Surface area of the tank.
Properties : Type 'vec' of size -1.
Altitude du piquage d entrée 1: ze1 (m)
Altitude of the first input port
Properties : Type 'vec' of size -1.
Altitude du piquage d entrée 2: ze2 (m)
Altitude of the second input port
Properties : Type 'vec' of size -1.
Altitude du piquage de sortie 1: zs1 (m)
Altitude of the first output port.
Properties : Type 'vec' of size -1.
Altitude du piquage de sortie 2: zs2 (m)
Altitude of the second output port.
Properties : Type 'vec' of size -1.
Altitude initiale du fluide : z0 (m)
Initial fluid level in the tank.
Properties : Type 'vec' of size -1.
Température initiale du fluide : T0 (K)
Temperature of fluid in the tank
Properties : Type 'vec' of size -1.
Si 0, masse volumique imposée du fluide : p_rho (kg/m3)
Density of fluid
Properties : Type 'vec' of size -1.
Default properties
Inputs :
Modelica variable name : 'Ce1'
Implicit variable.
Modelica variable name : 'Ce2'
Implicit variable.
Outputs :
Modelica variable name : 'Cs1'
Implicit variable.
Modelica variable name : 'Cs2'
Implicit variable.
Modelica variable name : 'yNiveau'
Explicit variable.
Parameters :
Modelica parameter name : 'Patm'
Default value : 101300
Is a state variable : no.
Modelica parameter name : 'A'
Default value : 1
Is a state variable : no.
Modelica parameter name : 'ze1'
Default value : 40
Is a state variable : no.
Modelica parameter name : 'ze2'
Default value : 0
Is a state variable : no.
Modelica parameter name : 'zs1'
Default value : 40
Is a state variable : no.
Modelica parameter name : 'zs2'
Default value : 0
Is a state variable : no.
Modelica parameter name : 'z0'
Default value : 30
Is a state variable : no.
Modelica parameter name : 'T0'
Default value : 290
Is a state variable : no.
Modelica parameter name : 'p_rho'
Default value : 0
Is a state variable : no.
File name of the model : Bache
Interfacing function
SCI/modules/scicos_blocks/macros/Hydraulics/Bache.sci
Modelica model
SCI/modules/scicos_blocks/macros/Hydraulics/Bache.mo
Report an issue | ||