Please note that the recommended version of Scilab is 2025.0.0. This page might be outdated.
See the recommended documentation of this function
INTEGRAL_m
Integration
Block Screenshot
Contents
Description
This block is an integrator. The output y is the integral of the input u at the current time step t.
Parameters
The parameter dialog box allows you to define:
The initial condition with or without saturation limit.
The upper and lower limits on the integral.
The dialog box also allows you to add an event port to the block in order to reset its state to a specified initial condition.
If ”reinitialization” is selected the following yields:
The value to be integrated shall be connected to the integral block port number 1. (the port in the upper left corner of the integral block)
The value that the integrator shall initiate to, at each trigger signal on the red marked trigger port, shall be connected to the integral block port number 2. (the port in the lower left corner of the integral block).
Initial Condition
A vector/scalar initial conditions.
With that parameter, one can define the datatype of the input/output. It can be a real or a complex type.
Properties : Type 'mat' of size [-1,-1].
With reinitialization
To reset its state to the specified initial condition based on an external signal select1 .
Properties : Type 'vec' of size 1.
With saturation
If selected, limits the states to a value between the Lower saturation limit and Upper saturation limit parameters.
Properties : Type 'vec' of size 1.
Upper limit
The upper limit for the integral.
Properties : Type 'mat' of size [-1,-1].
Lower limit
The lower limit for the integral.
Properties : Type 'mat' of size [-1,-1].
Default properties
always active: yes
direct-feedthrough: no
zero-crossing: no
mode: no
regular inputs:
- port 1 : size [1,1] / type 1
regular outputs:
- port 1 : size [1,1] / type 1
number/sizes of activation inputs: 0
number/sizes of activation outputs: 0
continuous-time state: yes
discrete-time state: no
object discrete-time state: no
name of computational function: integral_func
Interfacing function
SCI/modules/scicos_blocks/macros/Linear/INTEGRAL_m.sci
Computational function
- SCI/modules/scicos_blocks/src/c/integral_func.c
- SCI/modules/scicos_blocks/src/c/integralz_func.c
Examples
Example 1
This sample model demonstrates how to use the integrator's state port.
The reinitialization parameter is set to 1, the Upper limit to 1 and the lower limit to -1.
Example 2
Report an issue | ||