Please note that the recommended version of Scilab is 2025.0.0. This page might be outdated.
See the recommended documentation of this function
M_SWITCH
Multi-port switch
Block Screenshot
Contents
Palette
Description
The Multi-Port Switch block chooses between a number of inputs. The first (top) input is called the control input, while the rest of the inputs are called data inputs. The value of the control input determines which data input is passed through to the output port.
Dialog box
number of inputs
Specify the number of data inputs to the block.
Properties : Type 'vec' of size 1
zero base indexing
If selected, the block uses zero-based indexing. Otherwise, the block uses one-based indexing.
Properties : Type 'vec' of size 1
rounding rule: int
Select the rounding mode for the output.
Properties : Type 'vec' of size 1
Default properties
always active: no
direct-feedthrough: yes
zero-crossing: no
mode: no
regular inputs:
- port 1 : size [1,1] / type 1
- port 2 : size [-1,1] / type 0
- port 3 : size [-1,1] / type 1
regular outputs:
- port 1 : size [-1,1] / type 1
number/sizes of activation inputs: 0
number/sizes of activation outputs: 0
continuous-time state: no
discrete-time state: no
object discrete-time state: no
name of computational function: mswitch
Interfacing function
SCI/modules/scicos_blocks/macros/Branching/M_SWITCH.sci
Computational function
SCI/modules/scicos_blocks/src/c/mswitch.c (Type 4)
Report an issue | ||