SWITCH2_m

Switch2

Block Screenshot

Description

The Switch block passes through the first (top) input or the third (bottom) input based on the value of the second (middle) input. The first and third inputs are called data inputs. The second input is called the control input. You select the conditions under which the first input is passed with the Criteria for passing first input parameter. You can make the block check whether the control input is greater than or equal to the threshold value, purely greater than the threshold value, or nonzero. If the control input meets the condition set in the Criteria for passing first input parameter, then the first input is passed. Otherwise, the third input is passed.

Dialog box

  • Datatype(1= real double 2=Complex)

    a scalar. Give the datatype of the inputs/output.

    Properties : Type 'vec' of size 1

  • Pass first input if: u2 =a

    Select the conditions under which the first input is passed. You can make the block check whether the control input is greater than or equal to the threshold value, purely greater than the threshold value, or nonzero. If the control input meets the condition set in this parameter, then the first input is passed. Otherwise, the third input is passed.

    Properties : Type 'vec' of size 1.

  • Threshold a

    Assign the switch threshold that determines which input is passed to the output.

    Properties : Type 'vec' of size 1.

  • Use zero crossing: yes

    Select to enable zero crossing detection.

    Properties : Type 'vec' of size 1.

Default properties

  • always active: no

  • direct-feedthrough: yes

  • zero-crossing: yes

  • mode: yes

  • regular inputs:

    - port 1 : size [-1,-2] / type 1

    - port 2 : size [1,1] / type 0

    - port 3 : size [-1,-2] / type 1

  • regular outputs:

    - port 1 : size [-1,-2] / type 1

  • number/sizes of activation inputs: 0

  • number/sizes of activation outputs: 0

  • continuous-time state: no

  • discrete-time state: no

  • object discrete-time state: no

  • name of computational function: switch2_m

Interfacing function

  • SCI/modules/scicos_blocks/macros/Branching/SWITCH2_m.sci

Computational function

  • SCI/modules/scicos_blocks/src/c/switch2_m.c (Type 4)

Example

Report an issue