Scilab Website | Contribute with GitLab | Mailing list archives | ATOMS toolboxes
Scilab Online Help
2025.0.0 - 日本語


PuitsP

Thermal-hydraulic drain (well)

Block Screenshot

Description

This thermal-hydraulic component represents a thermal-hydraulic constant pressure drain (well). This block is specified with its pressure and temperature. Conventionally, the flow direction is positive when fluid flows into the block.

Parameters

/>
  • Pression de la source : P0 (Pa)

    Pressure of the thermohydraulic source.

    Properties : Type 'vec' of size -1.

  • Temperature de la source : T0 (K)

    Temperature of the thermohydraulic source.

    Properties : Type 'vec' of size -1.

  • Enthalpie spécifique de la source : H0 (J/kg)

    Specific Enthaly of the thermohydraulic source.

    Properties : Type 'vec' of size -1.

  • 1:température fixée - 2:enthalpie fixée : option_temperature

    Temperature option. 1: fixed temperature - 2: fixed enthalpy

    Properties : Type 'vec' of size -1.

Default properties

  • Inputs :

    • Modelica variable name : 'C'

      Implicit variable.

  • Parameters :

    • Modelica parameter name : 'P0'

      Default value : 100000

      Is a state variable : no.

    • Modelica parameter name : 'T0'

      Default value : 290

      Is a state variable : no.

    • Modelica parameter name : 'H0'

      Default value : 100000

      Is a state variable : no.

    • Modelica parameter name : 'option_temperature'

      Default value : 1

      Is a state variable : no.

  • File name of the model : Puits

Interfacing function

  • SCI/modules/scicos_blocks/macros/Hydraulics/PuitsP.sci

Modelica model

  • SCI/modules/scicos_blocks/macros/Hydraulics/Puits.mo

Report an issue
<< PerteDP Thermohydraulics palette SourceP >>

Copyright (c) 2022-2024 (Dassault Systèmes)
Copyright (c) 2017-2022 (ESI Group)
Copyright (c) 2011-2017 (Scilab Enterprises)
Copyright (c) 1989-2012 (INRIA)
Copyright (c) 1989-2007 (ENPC)
with contributors
Last updated:
Thu Oct 24 11:17:46 CEST 2024