ccontrg
Central H-infinity continuous time controller
Syntax
K = ccontrg(P, r, gamma)
Arguments
- P
 a continuous time linear dynamical system in state-space representation.
- r
 a two elements vector with integer values: the dimension of the 2,2 part of
P- gamma
 real number
Description
returns a realization K of the central controller for the
            general standard problem in state-space form.
![]()  | Note that gamma must be > gopt (output of  gamitg) | 
P contains the parameters of plant realization (A,B,C,D)
            (syslin list) with
B = ( B1 , B2 ) , C= ( C1 ) , D = ( D11 D12) ( C2 ) ( D21 D22)
r(1) and r(2) are the
            dimensions of D22 (rows x columns)
See also
Authors
P. Gahinet (INRIA);
History
| Version | Description | 
| 5.4.0 | Sl is now checked for continuous time linear dynamical system.
                    This modification has been introduced by this  commit | 